Burn Room

The Fire Marshall

2

Stories

1

Burn Rooms

Overview

Tower Details

The Fire Marshall tower incorporates features from both the Fire Chief model and the Commissioner, with an overall length of 66’. The floor doors in the center of the tower allow for 3’ wide hallways all around (even when the floor door is open). Floor doors are aligned with each other on every floor, along with a 3’x3’ hatch on the roof. The floor doors and roof hatch provide built-in confined space training. This building offers the popular “L” shaped basement training stairs in the residence, along with a cantilevered balcony on the 2nd floor, and an exterior fire escape. The tower portion also includes an inset balcony on the 2nd floor.

Endless Training Scenarios

Vertical Confined Spaces
Ventilation
Room Search / Clearing
Riser Operation
Live Fire Attack
Laddering and Rappelling
Helicopter Deployment
Forced Entry

Training Tower

2-Story
Tower

Dimensions 18’L x 22’W x 40’H
Roof Flat
Roof Live Load 100 PSF
Wind Load Per Local Codes
Deck Live Load 100 PSF

Included

  • Parapet Roof Guard with Chained Opening
  • Interior “U” Shaped Stair to 4th Floor
  • Interior Fixed Ladder, 4th Floor to Roof
  • (1) 3’x7′ Exterior Steel Door
  • (3) 3’x4′ Window Openings with Steel Shutters
  • (2) Roof Hatches
  • (3) Floor Doors

Residential Section

Gable-Roof
Residence

Dimensions 34’L x 22’W x 27’H
Roof 16° Gable
Roof Live Load 100 PSF
Wind Load Per Local Codes
Deck Live Load 100 PSF

Included

  • Interior “L” Shaped Stair to 2nd Floor
  • (4) 3’x7′ Exterior Steel Doors
  • (5) 3’x7′ Interior Steel Doors
  • (1) 6’x7′ Exterior Double Leaf Steel Door
  • (8) 3’x4′ Window Openings with Steel Shutters
  • (2) 3’x3′ Hinged Gable Louvers
  • (2) 4’x4′ Roof Chop-Out Curbs
  • (1) 4’x35′ Cantilevered Balcony with Fire Escape
  • (1) 2nd Floor Burn Room
  • (1) Westec® Insulation System

Burn room annex

Single-Story
Annex

Dimensions 14’L x 22’W x 10’H
Roof 1/2″ in12″ Single Pitch
Roof Live Load 100 PSF
Wind Load Per Local Codes

Included

  • (1) 3’x7′ Exterior Steel Door
  • (2) 3’x4′ Window Openings with Steel Shutters
  • (1) Westec® Insulation System
  • (1) Scout Temperature Monitoring System

Training Tower

Two Story (18’ - 20’ H) story tower

Dimensions 18’L x 22’W x 40’H
Roof Flat
Roof Live Load 100 PSF
Wind Load Per Local Codes
Deck Live Load 100 PSF

Included

  • Parapet Roof Guard with Chained Opening
  • Interior “U” Shaped Stair to 4th Floor
  • Interior Fixed Ladder, 4th Floor to Roof
  • (1) 3’x7′ Exterior Steel Door
  • (3) 3’x4′ Window Openings with Steel Shutters
  • (2) Roof Hatches
  • (3) Floor Doors

Burn room annex

Single-store annex

Dimensions 14’L x 22’W x 10’H
Roof 1/2″ in12″ Single Pitch
Roof Live Load 100 PSF
Wind Load Per Local Codes

Included

  • (1) 3’x7′ Exterior Steel Door
  • (2) 3’x4′ Window Openings with Steel Shutters
  • (1) Westec® Insulation System
  • (1) Scout Temperature Monitoring System

Residential Section

Gable-roof residence

Dimensions 34’L x 22’W x 27’H
Roof 16° Gable
Roof Live Load 100 PSF
Wind Load Per Local Codes
Deck Live Load 100 PSF

Included

  • Interior “L” Shaped Stair to 2nd Floor
  • (4) 3’x7′ Exterior Steel Doors
  • (5) 3’x7′ Interior Steel Doors
  • (1) 6’x7′ Exterior Double Leaf Steel Door
  • (8) 3’x4′ Window Openings with Steel Shutters
  • (2) 3’x3′ Hinged Gable Louvers
  • (2) 4’x4′ Roof Chop-Out Curbs
  • (1) 4’x35′ Cantilevered Balcony with Fire Escape
  • (1) 2nd Floor Burn Room
  • (1) Westec® Insulation System

Accessories

Configure it for the way you train

Balconies
Balcony, Cantilevered
Balcony, Inset
Balcony, Open Corner
Balcony, Supported
Burn Area, Attic
Burn Area, Corner
Burn Crib
Burn Room
Class A Burn Prop – Bed Simulator
Class A Burn Prop – Bunk Bed Simulator With Burnable Top Bunk
Class A Burn Prop – Movable Burn Bin
Class A Burn Prop – Stove Simulator With Enclosed Overhead Hood
Class A Burn Prop – Stove Simulator With Overhead Burn Hood
Confined Space Rescue Prop
Confined Space Vertical Rescue Prop, Removable
Elevator Shaft (Confined Space)
Manhole Frame/Cover
Doors
Floor Door
Forcible Entry Training System/Door
Heavy-Duty Spring Closer For Burn Room Doors
Ladder Hook Bar
Ladder, Caged
Ladder, Interior
Ladder, Ship’s
Rappel Railing
Rappelling Anchor, Swivel
Rappelling Platform
Smoke Distribution System
Smoke Generator
Temperature Monitoring
Fire Watchman Pyrometer
Scout Cellular Texting Alarm
Scout External Alarm
Scout External Alarm Horn
Scout Pyrometer with Bluetooth
Movable Half-Wall System/Maze
Movable Wall System/Maze
Movable Wall System/Maze with Working Door
Annunciator Visual/Audio Alarm Panel
Debris Catch Pan
Exhaust Fan
Exterior Stairs (Fire Escape)
Facade, Mortarless Brick
Helicopter Skid Simulator
LPG/Natural Gas Props
Multi-Level Platform
Open Story
Operating Lever Latch
Riser System (Fire Department Connection)
Roll-up Door
Slip-Resistant Paint Roof System
Slip-Resistant Roof Tape
Sprinkler System
Westemp® Insulating Panels

Land Area Requirements

Plan your site

Basic building site 1.00 acre
Drafting pit 0.20 acre
Vehicle extrication pad 0.20 acre
Rail car spill 0.60 acre
Tank truck spill/roll-over 0.20 acre
Flammable liquid pond 0.10 acre
Electric transformer pad 0.10 acre
Aircraft rescue pad 0.70 acre
Classroom building 0.30 acre
Garage 0.30 acre

Get Started

Build The Fire Marshall for Your Department

Tell us about your training goals and site. Our team will help you configure this model, sections, accessories, and colors for the way you train.