Tower

The Probie

3

Stories

Burn Rooms

Overview

Tower Details

The Probie burn building design features a first and second floor as well as an attic. An interior fixed ladder provides access to the attic from the second floor. At a height of 25′, the burn building supports rappelling and laddering. In addition, the Probie’s sloped roof is ideal for various roof exercises.

Endless Training Scenarios

Vertical Confined Spaces
Ventilation
Room Search / Clearing
Riser Operation
Live Fire Attack
Laddering and Rappelling
Helicopter Deployment
Forced Entry

Training Tower

3-Story
Tower

Dimensions 22’L x 16’W x 25’H
Roof 16° Single Pitch
Roof Live Load 100 PSF
Wind Load Per Local Codes
Deck Live Load 100 PSF

Included

  • Interior Stair to 2nd Floor
  • Interior Fixed Ladder, 2nd Floor to Attic
  • (1) 3’x7′ Exterior Steel Door
  • (1) 3’x7′ Interior Steel Door
  • (6) 3’x4′ Window Openings with Steel Shutters
  • (1) 4’x4′ Roof Chop-Out Curb
  • (1) Drywall Curb

Burn room annex

Single-Story
Annex

Dimensions 14’L x16’W x 9’H
Roof 1/2″ in 12″ Single Pitch
Roof Live Load 100 PSF
Wind Load Per Local Codes

Included

  • (1) 3’x7′ Exterior Steel Door
  • (3) 3’x4′ Window Openings with Steel Shutters
  • (1) Westec® Insulation System
  • (1) Scout Temperature Monitoring System

Training Tower

Three Story (25’ - 30’H) story tower

Dimensions 22’L x 16’W x 25’H
Roof 16° Single Pitch
Roof Live Load 100 PSF
Wind Load Per Local Codes
Deck Live Load 100 PSF

Included

  • Interior Stair to 2nd Floor
  • Interior Fixed Ladder, 2nd Floor to Attic
  • (1) 3’x7′ Exterior Steel Door
  • (1) 3’x7′ Interior Steel Door
  • (6) 3’x4′ Window Openings with Steel Shutters
  • (1) 4’x4′ Roof Chop-Out Curb
  • (1) Drywall Curb

Burn room annex

Single-store annex

Dimensions 14’L x16’W x 9’H
Roof 1/2″ in 12″ Single Pitch
Roof Live Load 100 PSF
Wind Load Per Local Codes

Included

  • (1) 3’x7′ Exterior Steel Door
  • (3) 3’x4′ Window Openings with Steel Shutters
  • (1) Westec® Insulation System
  • (1) Scout Temperature Monitoring System

Accessories

Configure it for the way you train

Balconies
Balcony, Cantilevered
Balcony, Inset
Balcony, Open Corner
Balcony, Supported
Burn Area, Attic
Burn Area, Corner
Burn Crib
Burn Room
Class A Burn Prop – Bed Simulator
Class A Burn Prop – Bunk Bed Simulator With Burnable Top Bunk
Class A Burn Prop – Bunk Bed Simulator With Enclosed Top Bunk
Class A Burn Prop – Movable Burn Bin
Class A Burn Prop – Stove Simulator With Enclosed Overhead Hood
Class A Burn Prop – Stove Simulator With Overhead Burn Hood
Confined Space Rescue Prop
Confined Space Vertical Rescue Prop, Removable
Manhole Frame/Cover
Doors
Floor Door
Forcible Entry Fire Training Door
Forcible Entry Training System/Door
Ladder Hook Bar
Ladder, Caged
Ladder, Interior
Ladder, Ship’s
Rappelling Anchor, Swivel
Smoke Distribution System
Smoke Generator
Temperature Monitoring
Fire Watchman Pyrometer
Scout Cellular Texting Alarm
Scout External Alarm
Scout External Alarm Horn
Scout Pyrometer with Bluetooth
Movable Half-Wall System/Maze
Movable Wall System/Maze
Movable Wall System/Maze with Working Door
Annunciator Visual/Audio Alarm Panel
Debris Catch Pan
Exhaust Fan
Exterior Stairs (Fire Escape)
Facade, Mortarless Brick
LPG/Natural Gas Props
Multi-Level Platform
Open Story
Operating Lever Latch
Riser System (Fire Department Connection)
Roll-up Door
Slip-Resistant Paint Roof System
Slip-Resistant Roof Tape
Sprinkler System
Westemp® Insulating Panels

Land Area Requirements

Plan your site

Basic building site 1.00 acre
Drafting pit 0.20 acre
Vehicle extrication pad 0.20 acre
Rail car spill 0.60 acre
Tank truck spill/roll-over 0.20 acre
Flammable liquid pond 0.10 acre
Electric transformer pad 0.10 acre
Aircraft rescue pad 0.70 acre
Classroom building 0.30 acre
Garage 0.30 acre

Get Started

Build The Probie for Your Department

Tell us about your training goals and site. Our team will help you configure this model, sections, accessories, and colors for the way you train.